MineARC’s Satellite Uninterruptible Power Supply (SUPS) System is a unique, portable battery bank; removing the need for battery and inverter storage at the rear of the refuge chamber. Major features of SUPS includes safer battery replacement, charge balancing, temperature cooling, and improved battery monitoring and diagnostics through MineARC’s GuardIAN.
MineARC’s Satellite Uninterruptible Power Supply (SUPS) System has been engineered specifically for use in conjunction with refuge chambers; designed to provide a solution to manual handling injuries and to ensure batteries perform at full capacity for their expected life span.
MineARC have nominated a battery life guarantee of three years to instill confidence in the design approach to battery management. By ensuring atmospheric conditions are optimal, monitoring battery activity and adding electronics to the charging system, the Satellite UPS System limits all primary aspects of battery degradation and allows MineARC’s high quality batteries to operate as intended. It would be expected that MineARC batteries will far exceed the three- year guarantee period, with some calculations indicating periods of as long as seven years.
Soft tissue injury caused by the manual handling of batteries during replacement is all too common in underground mines. Injuries are generally caused by factors including the design and position of battery
boxes, the weight of the batteries themselves, and the frequency in which batteries require replacement.
The portable design of MineARC’s Satellite UPS System means that it can be easily brought to the surface for maintenance or battery change out.
Reinforced sliding draws allows for safer lifting techniques during installation and removal of batteries; reducing risk of injury during battery replacement.
A common issue for many mine sites with refuge chambers is overcompensation of batteries within a thread. Delays or poor replacement practices often result in the need to replace a whole string of batteries; a costly and avoidable exercise.
MineARC’s Satellite UPS System features battery balancing technology that absorbs the charge from higher voltage batteries and transfers that charge to lower voltage batteries, thereby ensuring that all batteries within a string are charged equally. Balancing is achieved through the use of Linear Technology, LTC3305, and a Super Capacitor that is sequentially connected across the batteries in the stack.
Heat can have a significant effect on the performance and life-span of a battery, however high temperatures cannot always be avoided underground.
MineARC’s Satellite UPS System is a fully enclosed box that features an integrated air conditioner to provide complete temperature control.
The air conditioner will automatically maintain a constant temperature of 25°C within the battery box, protecting the batteries from over heating and ensuring they perform at full capacity for their expected life-span.
When used in conjunction with GuardIAN, the MineARC Satellite UPS System allows for real-time, remote monitoring of each individual battery.
Battery faults can be identified immediately via the GuardIAN Dashboard and Alert Feed, with auto-generated event notifications sent directly to any personal device. Voltage and temperature diagnostics for each individual battery within a string can also be viewed via a graph, highlighting any fluctuations over the past 24 hours.
MineARC batteries have been developed to operate in a variety of harsh environments around the world. Our knowledge and expertise in the
manufacturing of safety equipment for mining and heavy industry ensures that our batteries are able to withstand a multitude of extreme
weather conditions.
The model pictured below is a custom 44-battery unit. The larger battery capacity will help ensure the client has uninterrupted power for all their critical underground technology infrastructure when it’s needed most.
Ask us about a custom upgrade for additional battery capacity for your site.
Related Products
Refuge Chamber Monitoring
Refuge Chamber Monitoring Refuge Chamber Monitoring with GuardIAN is an exciting new development in refuge chamber technology. GuardIAN Refuge Chamber Monitoring enables real-time monitoring; providing confidence that an operation’s fleet of refuge chambers are emergency ready at all times. It is an independent system that continuously monitors all vital refuge operating systems. During standby mode, GuardIAN
Aura-FX Digital Gas Monitoring
Aura-FX Digital Gas Monitoring Aura-FX Digital Gas monitoring is an essential aspect of maintaining a life-supporting atmosphere within the refuge chamber. During entrapment, occupants consume oxygen and expire carbon dioxide (CO2) and carbon monoxide (CO) as part of their normal respiration. CO can also enter the chamber during occupant entry and if the compressed air
Compressed Air Management System (CAMS)
Compressed Air Management System (CAMS) The Compressed Air Management System (CAMS) is a breathable air system that is unique to the market; offering a range of features aimed at reducing running costs and improving operational safety during an emergency. Aside from providing clean breathable air through a superior four-phase filtration process, some of the major