AirMAX Life Support System
The AirMAX Life Support System design is for non-built-for-purpose buildings that do not meet acceptable leak tightness for shelter-in-place. With ventilation shut down, a typical building can have up to five air changes per hour or higher depending on wind speed. Door operation as people enter can potentially bring additional contaminants from outside the shelter. As contaminated air infiltrates a building, the level of protection provided to the occupants diminished with time.
A safer and more economical alternative is to seal smaller existing rooms with a larger building. There are cost-effective means to create a “very tight” room (<0.04CFM per square foot of floor space) within a building by using specifically designed components such as clean room ceiling tiles, sealing doors, and vestibules. These tightly sealed rooms, however, cannot be occupied for long periods without the risk of occupants producing a high level of carbon dioxide and dangerously reducing oxygen levels.
There are cost-effective means to create a pressurised shelter or ‘very tight’ room.
The MineARC AirMAX Life Support System combines two critical life support features. A Positive Pressure Maintenance System (PPMS) to keep toxic and hazardous gases out, and a supplemental oxygen delivery system to replenish the air. Optional Aura-FX Gas Monitoring ensures that external contaminants cannot enter the sealed room, while alerting users to changes in gas levels.
- Mobile design for easy relocation
- Oxygen and compressed air cylinder storage
- Oxygen Delivery System
- Positive Pressure Maintenance System (>0.14psi)
- 120/240V electrical connection
- Optional Aura-FX Gas Monitoring (NH3, CL etc.)
- Occupancy: 4 Hours
- Voltage: 120V or 240V
- Depth: 36.25in (0.92m)
- Width: 25.25in (0.62m)
- Height: 76in (1.93m)
- Weight (Est.): 1,100lbs (500kg)
AirBANK Pressure System
AirBANK provides rapid pressurization, which is activated and maintained using the AirBANK CONTROL via a simple HMI touch screen. MineARC’s integrated Aura-FX Gas Monitor ensures breathable air remains within acceptable limits. Alternatively, ChemSAFE Sealed Rooms can be fitted with supplementary oxygen and carbon dioxide scrubbing systems.
AirBANK CONTROL features an active by-pass of the system if internal gas levels are not within breathable air limits. The Aura-FX monitors and displays gas levels in real-time, including site-specific toxic gases if necessary.
AirGEN Scrubbing System
Depending on the designated occupancy of the petrochemical facility’s sealed room location and volume, CO2 removal may be required. The MineARC AirGEN is a standalone air regenerative system that ‘scrubs’ the air inside of an enclosed location, effectively cleaning it so occupants can breathe.
Humans consume oxygen and expire carbon dioxide (CO2) as part of normal respiration. In high enough concentrations, CO2 can cause serious injury, leading to a loss of consciousness and eventually death. Removal of CO2 is therefore a vital necessity for any shelter-in-place location, especially where CO2 concentrations exceed one percent over the entrapment duration.
The AirGEN is simple to operate with only a single switch and is powered from its own internal battery supply.
Shelter-in-Place Integrity Testing
MineARC Systems have the testing ability in-house that allows us to establish baseline integrity readings and provide a greater indication of your current level of protection against ingress.
Our integrity testing system is engineered to be portable and able to travel to individual sites for verification and auditing purposes and is ideal for generating an accurate baseline position for risk assessment.
Contact MineARC to have your site tested.
Related Products
Stench Gas Systems
Stench Gas Systems for Emergency Alerts An Emergency Stench Gas Alert System is commonly used in underground ventilation systems as a warning gas for emergency evacuations. The powerful odour can be quickly dispersed throughout an underground mine to alert workers of impending danger. The MineARC Stench Gas Emergency Alert System is designed to suit noisy locations where
Aura-FX Digital Gas Monitoring
Aura-FX Digital Gas Monitoring Aura-FX Digital Gas monitoring is an essential aspect of maintaining a life-supporting atmosphere within the refuge chamber. During entrapment, occupants consume oxygen and expire carbon dioxide (CO2) and carbon monoxide (CO) as part of their normal respiration. CO can also enter the chamber during occupant entry and if the compressed air